SIOM OpenIR  > 高功率激光物理国家实验室
Measurement Technique of Signal Noise Ratio Based on Resonator Oscillation for Femtosecond Single-Shot Pulse
Shi SX(石帅旭); Yang QW(杨庆伟); 欧阳小平; Xia SQ(夏素秋); Zhu JQ(朱建强); shuaixushi@hotmail.com; jqzhu@mail.shcnc.ac.cn
2016
发表期刊中国激光
卷号43期号:9页码:904001
摘要A measurement technique of signal noise ratio based on resonator oscillation for single-shot pulse is proposed. Through precise setting of the resonant cavity length, optical path difference between two resonant cavities, and the reflectivity or transmittance of the high reflectivity mirror, the three key indicators of high dynamic range, large time window and high temporal resolution are easily realized. Meanwhile, high fidelity of measurement signal is guaranteed using full aperture beam measurement. Theoretically, various kinds of function and stability of the resonator structure are analyzed. Influence of errors introduced by dispersion on results are also analyzed. High reflectivity mirrors with wedge-shape are introduced in the resonator cavity to avoid the noise of minor pulses. In theory, the measurement of high signal noise ratio (10~(10) ) , even higher signal noise ratio, and high temporal resolution of hundred femtosecond can be realized in this construction.
文章类型Article
其他摘要提出了一种谐振腔振荡式单次脉冲信噪比测量技术,通过精确设置谐振腔长度、两谐振腔之间的光程差、高反镜的反射或透射率,可简便地实现信噪比测量中高动态范围、大时间窗口和高时间分辨率三个关键指标。同时,采用全口径光束测量,保证了测量信号的高保真度。从理论上分析了谐振腔结构的各种功能和稳定性,以及色散引起的误差影响,在谐振腔中引入楔形高反镜,避免了次脉冲噪声的产生。理论上,该种结构可以实现10~(10),甚至更高信噪比的测量,而且能达到百飞秒的高时间分辨率。
部门归属联合
DOI10.3788/CJL201643.0904001
资助者惯性约束聚变能源先期关键技术合作研究 ; 惯性约束聚变能源先期关键技术合作研究 ; 惯性约束聚变能源先期关键技术合作研究 ; 惯性约束聚变能源先期关键技术合作研究
收录类别CSCD
资助者惯性约束聚变能源先期关键技术合作研究 ; 惯性约束聚变能源先期关键技术合作研究 ; 惯性约束聚变能源先期关键技术合作研究 ; 惯性约束聚变能源先期关键技术合作研究
WOS记录号CSCD:5798594
CSCD记录号CSCD:5798594
引用统计
文献类型期刊论文
条目标识符http://ir.siom.ac.cn/handle/181231/27970
专题高功率激光物理国家实验室
通讯作者shuaixushi@hotmail.com; jqzhu@mail.shcnc.ac.cn
作者单位中国科学院上海光学精密机械研究所
推荐引用方式
GB/T 7714
Shi SX,Yang QW,欧阳小平,et al. Measurement Technique of Signal Noise Ratio Based on Resonator Oscillation for Femtosecond Single-Shot Pulse[J]. 中国激光,2016,43(9):904001.
APA 石帅旭.,杨庆伟.,欧阳小平.,夏素秋.,朱建强.,...&jqzhu@mail.shcnc.ac.cn.(2016).Measurement Technique of Signal Noise Ratio Based on Resonator Oscillation for Femtosecond Single-Shot Pulse.中国激光,43(9),904001.
MLA 石帅旭,et al."Measurement Technique of Signal Noise Ratio Based on Resonator Oscillation for Femtosecond Single-Shot Pulse".中国激光 43.9(2016):904001.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[石帅旭]的文章
[杨庆伟]的文章
[欧阳小平]的文章
百度学术
百度学术中相似的文章
[石帅旭]的文章
[杨庆伟]的文章
[欧阳小平]的文章
必应学术
必应学术中相似的文章
[石帅旭]的文章
[杨庆伟]的文章
[欧阳小平]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。