SIOM OpenIR  > 高功率激光物理国家实验室
Design and calibration of hot-electron spectrometer array for angle-resolved measurement
Liu, Huiya; An, Honghai; Shen, Jie; Kang, Ning; Zhou, Shenlei; Lei, Anle; Lin, Zunqi; LAL@siom.ac.cn; zqlin@mail.shcnc.ac.cn
2017
Source PublicationRev. Sci. Instrum.
Volume88Issue:5
AbstractA hot-electron spectrometer array with two-dimensional distribution has been designed with a wide-angle range and high-energy resolution to measure the spatially resolved electron spectra for high-power-laser plasma interaction experiments. It consisted of 19 identical electron spectrometers set in three directions with an interval of 10 degrees. Each electron spectrometer was designed with a uniform magnetic field to detect electrons in the range from 20 to 500 keV. The spectrometers were calibrated using electrons from an accelerator. In an experiment, the spatially resolved electron energy spectra, which approximately had a Maxwell distribution, were obtained from an aluminum foil target irradiated by a 0.53-mu m m laser pulse. Published by AIP Publishing.
SubtypeArticle
Department联合
DOI10.1063/1.4982619
Funding OrganizationChinese Academy of Sciences [CXJJ-15S114] ; Chinese Academy of Sciences [CXJJ-15S114] ; Chinese Academy of Sciences [CXJJ-15S114] ; Chinese Academy of Sciences [CXJJ-15S114]
Indexed BySCI
Funding OrganizationChinese Academy of Sciences [CXJJ-15S114] ; Chinese Academy of Sciences [CXJJ-15S114] ; Chinese Academy of Sciences [CXJJ-15S114] ; Chinese Academy of Sciences [CXJJ-15S114]
WOS IDWOS:000402801900032
Citation statistics
Document Type期刊论文
Identifierhttp://ir.siom.ac.cn/handle/181231/27947
Collection高功率激光物理国家实验室
Corresponding AuthorLAL@siom.ac.cn; zqlin@mail.shcnc.ac.cn
Affiliation中国科学院上海光学精密机械研究所
Recommended Citation
GB/T 7714
Liu, Huiya,An, Honghai,Shen, Jie,et al. Design and calibration of hot-electron spectrometer array for angle-resolved measurement[J]. Rev. Sci. Instrum.,2017,88(5).
APA Liu, Huiya.,An, Honghai.,Shen, Jie.,Kang, Ning.,Zhou, Shenlei.,...&zqlin@mail.shcnc.ac.cn.(2017).Design and calibration of hot-electron spectrometer array for angle-resolved measurement.Rev. Sci. Instrum.,88(5).
MLA Liu, Huiya,et al."Design and calibration of hot-electron spectrometer array for angle-resolved measurement".Rev. Sci. Instrum. 88.5(2017).
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Liu, Huiya]'s Articles
[An, Honghai]'s Articles
[Shen, Jie]'s Articles
Baidu academic
Similar articles in Baidu academic
[Liu, Huiya]'s Articles
[An, Honghai]'s Articles
[Shen, Jie]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Liu, Huiya]'s Articles
[An, Honghai]'s Articles
[Shen, Jie]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.